Service manual
D-47
(7) Cleaning of the AIDC Sensor Board
(8) Cleaning of the PC Drum Paper Separator Fingers
(9) Removal of the Toner Antispill Seal
3. Turning the Bucket Roller, pour fresh developer
evenly into the chamber.
NOTES
• Shake the packet of developer well before opening
it.
• When the developer has been replaced, clear the
counts of “Developer 1” and “Developer 2” of “PM” of
“Counter” available from the Tech. Rep. mode and
run the F8 ATDC Sensor operation.
☞ D-81
1134D051AA
1. Remove the PC Drum.
2. Using a brush or a soft cloth dampened with alco-
hol, clean the AIDC Sensor Board.
4002D136AA
1. Remove the PC Drum.
2. Using a brush or a soft cloth dampened with alco-
hol, clean the PC Drum Paper Separator Fingers.
NOTE
During the cleaning procedure, use care not to
scratch, bend, or otherwise damage the tips of the PC
Drum Paper Separator Fingers. Be also careful not to
get hurt with the tips.
4002D137AA
1. Remove the PC Drum Paper Separator Fingers
Assy.
2. Remove two screws and the Toner Antispill Plate
and Toner Antispill Seal.
4002D138AB