Service manual
D-24
(8) Cleaning of the Vertical Transport Rollers
(9) Removal of the Synchronizing Roller
1. Open the Upper Right Door.
2. Using a soft cloth dampened with alcohol, wipe
each roller clean of dirt.
4002D244AA
1. Swing down the Front Door and slide out the
Developing Unit.
2. Remove the Rear Cover.
3. Remove the Right Cover.
4. Remove five screws and the Cover.
4002D238AC
Cover
5. Remove five screws and the Master Board Mount-
ing Bracket Assy.
4002D069AC
6. Remove six screws and the board cover.
4002D068AC
7. Remove three screws and the Power Supply Board
Mounting Bracket Assy.
4002D070AB