Service manual
T- 6 7
(21) C10XX to C18XX
• These malfunctions are concerned with faulty symptoms relating to software, hardware,
and communications.
Code Action
C10XX
C11XX
C12XX
1. Reset the malfunction and turn OFF and ON the Power Switch.
2. If the same malfunction persists, check cables and connectors for proper
connection.
3. If they are okay, change Image Processing Board, Memory Board, or Hard
Disk Drive.
C12CX 1. Run “Hard Disk Format” selected in the following sequence: Tech. Rep.
Mode → Function → Image Memory.
2. If the same malfunction persists, change Hard Disk Drive.
3. If the malfunction is detected a third time, change Memory Board.
C1300 1. Reset the malfunction and turn OFF and ON the Power Switch.
2. If the same malfunction persists, check connectors of Polygon Motor and
Master Board.
3. If connections are okay, change PH Unit, Master Board, or Power Supply
Board.
C1326 1. Reset the malfunction and turn OFF and ON the Power Switch.
2. If the same malfunction persists, change Memory Board or Master Board.
C1330
C1334
1. Reset the malfunction and turn OFF and ON the Power Switch.
2. If the same malfunction persists, run “Mem. → Prn” selected from “I.R.
Mem. Prn” selected in the following sequence: Tech. Rep. Mode →
Function → Image Memory.
3. If the malfunction is detected a third time, change Master Board or Image
Processing Board.
C133B 1. Reset the malfunction and turn OFF and ON the Power Switch.
2. Check the option I/F cable for proper connection.
3. If the connection is okay, change the CPU Board of the option, or Master
Board.
C13F1 1. Reset the malfunction.
2. If the same malfunction persists, check the Image Processing Board connec-
tor for proper connection.
3. If the connection is okay, change the PH Unit, Image Processing Board, or
Master Board.
C13F4~
C13F8
C13FAB
C13FC
1. Reset the malfunction.
2. If the same malfunction persists, change the PH Unit.
3. If the same malfunction is detected again, change the PH Unit.
4. If the malfunction is detected a third time, change Image Processing Board.
C13F9 1. Reset the malfunction.
2. If the same malfunction persists, change the Master Board.
→
→
→
→