Service manual
T- 6 5
(19) C0F24: AIDC Sensor contamination correction failure
C0F24
Relevant Electrical Parts
AIDC Sensor Board (PWB-G) Master Board (PWB-A)
Step Check Result Action
1 PJ7A, CN10, and CN41 are plugged securely
into Master Board.
NO Plug them in securely.
2 Photosensor/LED of the AIDC Sensor are con-
taminated.
YES Clean.
NO Change AIDC Sensor
Board.
Change Master Board.
11
2424
1212
1111
1010
CN10
3
2
1
1
2
3
CN41
PWB-A
PWB-G
AIDC
PJ7A-5B(AIDC LED)
PJ7A-6B(GND)
PJ7A-7B(AIDC OUT)
4002C21TAA