Service manual

S-36
(9) Level History
Displays the various level histories.
Touch Panel
Display
Setting
Date/Time Set Set the date and time-of-day for Date Printing.
Common DT Displays the screens for communications settings.
Dial Mode Sets the type of telephone line of the user.
Auto Receive Sets the auto reception function.
Touch Panel
Display
Setting
Fuser (Upper) Displays the current value of the fusing temperature.
Fuser (Lower) Displays the current value of the fusing temperature.
ATDC Set Displays the voltage set with ATDC Sensor Automatic Adjustment
(F8).
ATDC Current Displays the output voltage of the ATDC Sensor.
AIDC Fine Set Displays the AIDC Sensor LED control voltage.
AIDC Coarse Set Displays the load resistance level of the phototransistor used in the
AIDC Sensor.
AIDC Current Displays the output voltage of the AIDC Sensor.
Vg Current Displays the current value of the grid voltage.
Vb Current Displays the current value of the developing bias voltage.
LD1 Displays the intensity value of LD1.
LD2 Displays the intensity value of LD2.
Tone Pulse
YES
NO