Service manual
S-6
(1) Clearing Procedures
<Initialize>
1. Turn OFF the Power Switch.
2. With the circuit across pins of PJ2 closed, turn ON the Power Switch.
3. Open the circuit in about 5 seconds.
4. Check that the message “Initialize Completed” is displayed on the Touch Panel and then
touch the “OK” key.
<Memory Clear>
1. Turn OFF the Power Switch.
2. With the circuit across TP1 and TP3 closed, turn ON the Power Switch.
3. Open the circuit in about 5 seconds.
4. Check that the message “Memory Clear Completed” is displayed on the Touch Panel
and then touch the “OK” key.
NOTES:
• If the copier exhibits an erratic display or operation, reset and clear in the following order:
Initialize
→
Memory Clear.
• If Memory Clear has been performed, make settings of various functions once again.
(2) Data/Conditions Cleared by Reset Switches/Pins
❍: Cleared –: Not cleared
Clearing Method
Data Cleared
Front Door
Open/Close
Trouble Reset
Switch S25
Initialize
PJ2
Memory
Clear
TP1
Misfeed display ❍ – ❍❍
Malfunction
display
Fusing/
Optical
– ❍❍❍
Others ❍❍❍❍
Erratic operation/display – ❍❍❍
Job/Image – – – ❍
User’s Choice – – – ❍
Tech. Rep. Mode – – – ❍
Security Mode – – – ❍