10. Call the Adjust mode to the screen.
11. Touch [IR].
12. Touch [Scale (FD)].
Setting Instructions
If the position of the leading edge of the scale reproduced on the enlarged copy deviates
from that on the full-size copy, decrease the setting value.
If the leading edge of the scale is not reproduced on the full-size copy, increase the setting
value.
15. Go back to the Basic screen.
16. Perform steps 6 through 9.
17. Check to see if conditions of steps 8 and 9 are met.
If the conditions are not met, try another setting value for rechecking.
18. If the conditions are met, return Lead Edge Erase, Registration (FD), and Erasure
Width to the values recorded.
13. Press the Clear key to clear the current
setting value.
4002D510CB
Usetoclearthe
setting value.
Usetoenterthe
setting value.
Use to change the
+ or - sign.
4
7
5
8
0
3
6
9
C
14. Use the 10-key pad to change the setting
value.
NOTE
Use the Access key to select the sign of
+or-.
4002D537CA
Setting Value