FrameMaker Ver.5.5(PC) Di350 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.11.25
S-20
Tech. Rep. Mode Tech. Rep. Choice
<ADFR>
Touch Panel
Display
Setting (The default is ).
Image Density Set the image density for the printer.
✽
The value set for this function becomes the central value of “Print
Exposure” of User’s Choice.
ATDC Sensor
Gain
Current: Shows the current ATDC control voltage.
Set: Set the ATDC control voltage.
✽
If the “Set” value is to be changed, be sure to record the “Current”
value.
✽
The ATDC Sensor Gain value can be converted to a voltage value
using the following equation.
ATDC Sensor Gain = 5.1 × 2.2 × [setting value]
÷
256 (V)
VG Adjust Set VG when a fog or void occurs in the image.
Touch Panel
Display
Setting (The default is ).
Original Stop
Position
Set the document stop position in each of the ADFR modes.
✽
The minimum setting value is -6 only for 2-Sided Set.
Registration Loop Set the loop length to be formed in the original before the Registration
Roller of ADFR.
Highlighted
-2.............................. ........................... +4
Lighter Darker
0
123......................... ...................... 186
T/C Greater T/C Smaller
155
-2.............................. ........................... +2
Lighter Darker
0
Highlighted
1-Sided Set
-7.............................. .......................... +7
2-Sided Set
Single Feed Set
0
Original Width
Scale end
Original Glass
end
-5mm........................ ..................... +5mm
Smaller Greater
0