Service manual

FrameMaker Ver.5.5E(PC) Di350 DIS/REASSEMBLY, ADJUSTMENT
98.12.09
D-52
If the Scanner/Mirrors Carriage Positioning Jigs are not available, follow these steps to
make the adjustment.
NOTE
If the Scanner does not run parallel with the 2nd/3rd
Mirrors Carriage when the Scanner/Mirrors Carriage
Positioning Jigs are in position, turn the adjusting
screw for the rear Scanner Drive Cable as necessary.
1167D116AB
Adjusting Screw
1. Temporarily loosen the set screws of the cable
holding plate of the Scanner Drive Cable.
1167D113AA
2. Obtain a distance of 13 mm between the 2nd/3rd
Mirrors Carriage and rail.
1167D117AC
13 mm
3. Secure the Scanner where it is located at a posi-
tion 21 mm from the right side face.
4. Tighten the set screws of the cable holding plate.
1167D118AC
21 mm
NOTE
If the Scanner does not run parallel with the 2nd/3rd
Mirrors Carriage, turn the adjusting screw for the rear
Scanner Drive Cable as necessary.
1167D116AB
Adjusting Screw