Service manual

FrameMaker Ver.5.5E(PC) Di350 DIS/REASSEMBLY, ADJUSTMENT
98.12.09
D-51
Focus-Positioning of the Scanner and 2nd/3rd Mirrors Carriage
NOTE
Make this adjustment after any of the following procedures has been performed:
After the Scanner Drive Cable has been replaced.
When the Scanner Fixing Bracket has been removed from the Scanner Drive Cable.
When the Scanner Drive Cable comes unwound.
Requirement
With the Scanner fixed to the Scanner Drive Cables, there should be no gap between the
Scanner/Mirrors Carriage Positioning Jig and the Scanner and also between the Scanner/
Mirrors Carriage Positioning Jig and the 2nd/3rd Mirrors Carriage.
Adjustment Procedure
3-6. OTHER ADJUSTMENTS
1. Remove the Exposure Lamp. (For details, see
steps 1 through 7, (8) Removal of the Scanner, 2-4
OPTICAL SECTION.)
2. Temporarily loosen the set screws of the cable
holding plate of the Scanner Drive Cable.
1167D113AA
3. Fit the Scanner/Mirrors Carriage Positioning Jigs in
the space between the Scanner and 2nd/3rd Mir-
rors Carriage.
1167D114AA
4. Press the Scanner up against the jig and 2nd/3rd
Mirrors Carriage and, at the same time, tighten the
set screws of the cable holding plate.
1167D115AC
Scanner/Mirrors Carriage Positioning Jig
2nd/3rd
Mirrors
Carriage
Scanner