Service manual
FrameMaker Ver.5.5E(PC) Di350 DIS/REASSEMBLY, ADJUSTMENT
98.12.09
D-50
Requirement
NOTE
This adjustment must be made when a shadow is produced from the Original Scale.
Adjustment Procedure
1. Call the Tech. Rep. mode to the screen.
2. Touch [Tech. Rep. Choice].
3. Touch [IR-Erasure Width] to enter the IR-Erasure Width mode.
4. Press the Clear key to clear the current setting.
5. Enter the new setting value from the 10-Key Pad.
Setting Instructions
To make the erase width along four edges of the paper smaller, decrease the setting value.
To make the erase width along four edges of the paper greater, increase the setting value.
6. Touch the [END] key to validate the setting value.
Caution
Be sure to touch the END key before returning to normal operation mode. If the Panel
Reset Key is used, the previous setting remains valid.
(9) IR-Erasure Width
Set so that the erase width along four edges of the
paper falls within the range of 0 to 3 mm.
Adjust Mode Setting Range
IR-Erasure Width 0 to 3
1171D062AA
A
A
A
A
1171D064CA
1167D069AA
Setting Value
Use to clear setting value.
Use to enter setting value.