FrameMaker Ver.5.5E(PC) Di350 TROUBLESHOOTING
98.12.09
T- 2 6
<Duplex Turnover/Take-Up Misfeed Troubleshooting Procedure>
Symptom Step Check Item Result Action
Paper is at a stop
near the exit sec-
tion.
1
Is the Paper Exit Roller
deformed, worn, or dirty with
paper dust?
YES
Clean or change the Paper Exit
Roller.
2
Is PC3 fully operational? Check
the input data using I/O Check.
NO
Check the PC3 actuator for oper-
ation and, if it is intact, change
PC3.
3
Check M1 for operation.
Does the voltage across PJ1A-7
on PWB-A (Duplex Main Board)
and GND change from DC5V to
DC0V during a 2-sided copy
cycle?
YES
Check gears for proper engage-
ment.
NO
Change PWB-A.
4
Does the voltage across PJ1A-5
on PWB-A (Duplex Main Board)
and GND change from DC5V to
DC0V during a 2-sided copy
cycle?
YES
Check various parts for possible
overload and, if they are okay,
change M1 or PWB-A (Duplex
Main Board).
NO
Change PWB-A.
Paper is at a stop
inside the Duplex
Unit.
1
Is the Duplex Unit Transport
Roller or Roll deformed, worn, or
dirty with paper dust?
YES
Clean or change the Duplex Unit
Transport Roller or Roll.
2
Is a torn piece of paper present
on the paper path surface?
YES
Remove the torn piece of paper.
3
Is the Manual Feed Take-Up
Roller or Roll deformed, worn, or
dirty with paper dust?
YES
Clean or change the Manual
Feed Take-Up Roller or Roll.
4
Check M2 for operation.
Does the voltage across PJ1A-3
on PWB-A (Duplex Main Board)
and GND change from DC5V to
DC0V during a 2-sided copy
cycle?
YES
Check gears for proper engage-
ment.
NO
Change PWB-A.
5
Is PI1 fully operational? Check
the input data using I/O Check.
NO
Check the PI1 actuator for opera-
tion and, if it is intact, change
PWB-A (Duplex Main Board).
6
Check CL3 for operation.
Does the voltage across CN14-2
and GND change from DC24V to
DC0V when paper is taken up
from the Duplex Unit?
YES
Check various parts for possible
overload and, if they are okay,
change CL3 or M2.
NO
Change PWB-A.
Paper is at a stop
near the Synchro-
nizing Rollers.
1
Is PC2 fully operational? Check
the input data using I/O Check.
YES
Check various parts for possible
overload and, if they are okay,
change PWB-A.
NO
Check the PC2 actuator for oper-
ation and, if it is intact, change
PC2.