Service manual
FrameMaker Ver.5.5(PC) Di350 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.11.25
S-41
•
This function is used to enter the adjustment values as they relate to the IR.
<Setting Procedure>
1. Touch [IR] to open the IR screen.
2. Select the desired subfunction.
Tech. Rep. Mode Adjust
(2) IR
Touch Panel
Display
Setting (The default is ).
Registration Adjust registration of the Scanner in the main and sub-scanning direc-
tions.
Main scaning (CD)
Sub scaning (FD)
Zoom Adjust Adjust the scanning zoom ratio of the Scanner in the main and sub-
scanning directions.
Highlighted
-72 dot.................................... ...................................+72 dot
Smaller
Greater
0
-24 dot.................................... .................................+127 dot
Smaller
Greater
0
0.990.................................. ..................................1.010
Smaller
Greater
1.000