<Removal of the PC Drum Charge Corona Assy>
<Removal of the Charge Neutralizing Sheet and Cleaning Blade>
<Cleaning of the PC Drum Paper Separator Fingers>
9. Remove the Ozone Filter.
10. Turn the holder in the rear in the direction of the
arrow to remove it from the side bracket.
11. Slide out the PC Drum Charge Corona in the
direction of the arrow.
12. Remove three screws, the Charge Neutralizing
Sheet, and Cleaning Blade.
NOTE
• When securing the Cleaning Blade and Charge
Neutralizing Sheet, tighten screws in the order of
one on one edge, one at the center, and one on
the other edge.
• When the Cleaning Blade has been replaced,
apply a coat of toner to the surface of the PC
Drum.
☞
D-34
13. Using a soft cloth dampened with alcohol, wipe
the Paper Separator Fingers clean of dirt.