FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
T- 6 1
Code Description Resetting Procedure
PLG Plug-In Counter not plugged in Plug in the Plug-In Counter.
Change setting in Security mode.
For details, see SWITCHES ON
PWBs/TECH. REP. SETTINGS.
Err A numeral outside the specified set-
ting range is entered.
Automatically reset 1 sec. after the
error display is given.
Turn OFF and ON the Power Switch.
Blank Mechanical total counter not con-
nected
Connect the mechanical total counter
and then turn OFF and ON the Power
Switch.
Change setting in Security mode.
For details, see SWITCHES ON
PWBs/TECH. REP. SETTINGS.
nc1 Maintenance Counter count value
reached (the set count of the Mainte-
nance Counter is reached)
Enter a count value again.
For details, see SWITCHES ON
PWBs/TECH. REP. SETTINGS.
nc2 IU life stop mode (the life value of the
Maintenance Counter is reached)
Initialize the counter value.
For details, see SWITCHES ON
PWBs/TECH. REP. SETTINGS.