Service manual

FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
T- 5 4
(8) Void areas
Section Step Check Result Action
Output
system
1 Foreign matter is present along the
paper path.
YES Remove foreign matter.
2 Paper dust plugs up the Paper Dust
Remover.
YES Clean or change.
3 PC Drum Charge Corona, grid mesh,
and Comb Electrode are loose.
YES Reinstall.
4 PC Drum Charge Corona contact is
dirty, scratchy, deformed, worn, or dam-
aged.
YES Clean, correct, or
change.
5 Developing Roller is dirty, scratchy,
deformed, worn, or damaged.
YES Clean or change.
6 Toner is even on Sleeve/Magnet Roller. NO Adjust DB.
For details, see DIS/
REASSEMBLY,
ADJUSTMENT.
7 Developer is not even in the Developer
Mixing Chamber of IU.
YES Even out developer in
the Developer Mixing
Chamber.
8 DB of IU is plugged with foreign matter
(such as paper dust).
YES Remove foreign matter.
9 Image Transfer Roller is dirty, scratchy,
deformed, worn, or damaged.
YES Clean, correct, or
change.
10 Image Transfer Roller Assy is installed
correctly.
NO Reinstall.
11 Charge Neutralizing Plate is dirty,
scratchy, folded, or bent.
YES Clean, correct, or
change.
12 Left Fusing Roller is dirty, scratchy,
deformed, or worn.
YES Clean or change.
NO Change IU.