4-2. Resetting Procedure by Malfunction Code
Code Description Resetting Procedure
C0000 Main Motor malfunction • Turn OFF and ON the Power Switch.
C0045 Fusing Cooling Fan Motor mal-
function
C004E Power Supply Cooling Fan Motor
malfunction
C0070 Toner Replenishing Motor mal-
function
C0210 Abnormal image transfer voltage
C03FF Improperly set Adjust Mode 11 • Set Adjust Mode 11 correctly and then
turn OFF and ON the Power Switch.
• For details, see SWITCHES ON PWBs/
TECH. REP. SETTINGS.
C0500 Warm-up failure • Turn ON the Power Switch with the Stop
key held down.
C0510 Abnormally low fusing temperature
C0520 Abnormally high fusing tempera-
ture
C0650 Faulty Scanner Home Position
Sensor
• Turn OFF and ON the Power Switch.
C0B60 Bin Switching Motor malfunction
C0F32 Faulty ATDC Sensor
C0F33 Improperly adjusted ATDC Sensor
C1038 Engine connection failure
C1200 Faulty ASIC/memory
C1300 Polygon Motor malfunction
C13F0 Faulty HSYNC
C1468 Faulty EEPROM
C14A3 IR fluorescent lamp fault