Service manual

FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
T- 2 2
4-2. Resetting Procedure by Malfunction Code
Code Description Resetting Procedure
C0000 Main Motor malfunction Turn OFF and ON the Power Switch.
C0045 Fusing Cooling Fan Motor mal-
function
C004E Power Supply Cooling Fan Motor
malfunction
C0070 Toner Replenishing Motor mal-
function
C0210 Abnormal image transfer voltage
C03FF Improperly set Adjust Mode 11 Set Adjust Mode 11 correctly and then
turn OFF and ON the Power Switch.
For details, see SWITCHES ON PWBs/
TECH. REP. SETTINGS.
C0500 Warm-up failure Turn ON the Power Switch with the Stop
key held down.
C0510 Abnormally low fusing temperature
C0520 Abnormally high fusing tempera-
ture
C0650 Faulty Scanner Home Position
Sensor
Turn OFF and ON the Power Switch.
C0B60 Bin Switching Motor malfunction
C0F32 Faulty ATDC Sensor
C0F33 Improperly adjusted ATDC Sensor
C1038 Engine connection failure
C1200 Faulty ASIC/memory
C1300 Polygon Motor malfunction
C13F0 Faulty HSYNC
C1468 Faulty EEPROM
C14A3 IR fluorescent lamp fault