Service manual

FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
T- 2 1
Code Description Detection Timing
C1200 Faulty ASIC/memory ASIC/memory (for image and control) fault
A write or read error occurs with SRAM on the Control
Board (PWB-C).
C1300 Polygon Motor mal-
function
Startup failure
A LOW Polygon Motor (M2) Lock signal is not
detected within a given period of time that begins 1
sec. after the Polygon Motor has started turning.
Lock signal fault: Unstable after the first Lock signal has
been detected
For a period of 1 sec. after the first LOW Polygon
Motor (M2) Lock signal (first Lock) has been detected,
the next LOW Polygon Motor Lock signal is not
detected.
Lock signal fault: Lock signal out-of-timing
A LOW Polygon Motor (M2) Lock signal is not
detected for a continuous given period of time while
the rotation of the Polygon Motor remains stabilized.
Faulty Lock signal
A LOW Polygon Motor (M2) Lock signal is detected for
a given period of time or more when the Polygon
Motor remains deenergized.
C13F0 Faulty HSYNC Laser scanning system malfunction
The SOS Sensor does not detect a rising edge of
SOS within a given period of time after the Polygon
Motor (M2) has started turning and a laser output has
been started.
The SOS Sensor detects no rising edges of SOS
while VIA (image area control) is ON.
C1468 Faulty EEPROM EEPROM fault
Data cannot be written in EEPROM.
Data stored in EEPROM is wrong.
C14A3 IR fluorescent lamp
fault
The Exposure Lamp (LA2) of the Scanner fails to turn
ON.
The intensity of the Exposure Lamp is a predeter-
mined value or less during shading and re-shading.