Service manual

FrameMaker Ver5.5E(PC) Di152/Di183 SWITCHES ON PWBs/TECH. REP. SETTINGS
01.07.26
S-28
5-3. Setting in the Adjust Mode
Code No.
Setting (The default is ).
--1
<Printer CD Registration adjustment>
Adjust registration in the CD direction on the printer (engine) side.
It is used when the PH Unit has been replaced.
--2
<Printer FD Registration adjustment>
Adjust registration in the FD direction on the printer (engine) side.
It is used when the PH Unit has been replaced.
--3
<Scanner CD Zoom adjustment>
Adjust the zoom ratio in the CD direction on the Scanner (IR) side.
It is used when the PH Unit or CCD Unit has been replaced.
--4
<Scanner FD Zoom adjustment>
Adjust the zoom ratio in the FD direction on the Scanner (IR) side.
It is used when the PH Unit or the Scanner Drive Cables have been
replaced, or when the Scanner has been removed.
--5
<Scanner CD Registration adjustment>
Adjust registration in the CD direction on the Scanner (IR) side.
It is used when the PH Unit or CCD Unit has been replaced.
--6
<Scanner FD Registration adjustment>
Adjust registration in the FD direction on the Scanner (IR) side.
It is used when the PH Unit or the Scanner Drive Cables have been
replaced, or when the Scanner has been removed.
Highlighted
Setting
60 .............................. ........................ 140
Description (mm) -4.................................0............................ +4
100
Setting
67 .............................. ........................ 133
Description (mm) -6.14............................0....................... +6.14
100
Setting
97.............................. ........................ 103
Description (%) -1.2 ..............................0 .........................+1.2
100
Setting
97.............................. ........................ 103
Description (%) -1.2 ..............................0 .........................+1.2
100
Setting
20 .............................. ........................ 180
Description (mm) -8.................................0............................ +8
100
Setting
60 .............................. ........................ 140
Description (mm) -4.................................0............................ +4
100