Service manual

FrameMaker Ver5.5E(PC) Di152/Di183 SWITCHES ON PWBs/TECH. REP. SETTINGS
01.07.26
S-16
(3) Tech.Rep.Choice
This function allows the Tech. Rep. to make various settings and adjustments.
<Procedure>
1. Enter the code number corresponding to the function to be used from the 10-Key Pad.
2. Press the Start key to display the current setting value.
3. Press the Clear key to clear the current setting value.
4. Enter the new setting value from the 10-Key Pad.
5. Press the Start key to validate the new setting value just entered.
If any value outside the available setting range is entered, the Display shows “Err”
rejecting the entry. (The old setting value will reappear on the Display 1 sec. later.)
<Exiting the Mode>
Press the Panel Reset key until the initial screen reappears.
Code No.
Setting (The default is ).
C-1
<Maintenance Counter Count>
Select the counting method of the maintenance counter.
It is used as guidelines for the number of copies to be made before
the next maintenance time.
C-2
<IU Life Stop>
Select whether to prohibit copying or not when the IU Counter
reaches a life value.
C-3
<ID Adjustment>
Set the central value of image density.
This function is used when image density is not satisfactory.
C-4
<VG Adjustment>
Vary the Vg voltage to adjust image density.
The function is used when a fog or a void occurs.
Increase the setting value to eliminate void.
Decrease the setting value to eliminate fog.
Highlighted
Setting Description
Not Count
1
Counted (Maintenance Indicator lights when a set-
ting value is reached.)
2
Counted (No new copy cycle can be initiated and
the Tech. Rep. Call LED lights when a setting value
is reached.)
0
Setting 1
Description Copying allowed Copying prohibited
0
Setting
0 1 2 4 5 6
Description
Lighter Darker
3
Setting
0 1 3 4
Description
Lighter Darker
2