Operation Manual
MINOLTAFAX 5600 Adjustment Procedures
3-53
3.9.1 Life Monitor
The life monitor displays the current software version, the total number of pages scanned, printed, and
transmitted, the number of drums replaced and the total page count on the current drum.
Note:
The All RAM Clear setting does not clear the life monitor. See page 3-68 to clear the life monitor.
1. Press
/PROGRAM
,
*
,
9, ENTER.
Life Monitor
2. Press
One-touch A (01) --- F (06)
to select the desired display. Press
STOP
to exit the test mode.
The following options are available:
One-touch
A
= displays software version
One-touch
B
= displays total pages scanned
One-touch
C
= displays total pages printed
One-touch
D
= displays total pages transmitted
One-touch
E
= displays drum replaced
One-touch
F
= displays total pages printed on current drum
If One-touch A (01) is selected, you’ll see the following message on the LCD.
Board Number?
Use the numeric keypad to select the optional board number as shown in the following table.
Fax model Numeric key
Flash ROM on Main control PWB 0
Built-in CPU ROM * (asterisk)
The software version of each board will be shown on the LCD.
Board Number?
0:MF5600 USA A0A0A0
The left most character on the lower line shows the board number selected.
Press STOP to exit to display the software version.
To select another display, press One-touch A (01) to F (06).
3. Press STOP to exit the test mode. The fax machine will retrun to standby mode.