ALUMA WET BY INSTRUCTION MANUAL WARRANTY CERTIFICATE
Manual design and all elements of manual design are protected by U.S. Federal and/or State Law, including Patent, Trademark and/or Copyright laws.
The Minka-Aire® warranty is for one (1) year from the date of purchase from an authorized Minka-Aire® dealer. This warranty is only valid to the original purchaser or user against all defects in material and workmanship (light bulbs excluded) for one (1) full year. Additionally, Minka-Aire® warrants the motor only for the lifetime of the Minka Aire ceiling fan (excluding wall controls and electrical components), to the original purchaser or user.
Warranty Service Information To obtain warranty service during the warranty period, the purchaser should return the fan with the sales receipt to the original place of purchase. The authorized Minka-Aire® dealer, at its sole discretion, will either repair or replace the fan after verifying the legitimacy of the warranty claim. Replacement is subject to availability of the same model. If the model is unavailable it will be replaced by one of equal value.
SAFETY RULES.....................................................................................1 INSTALLING THE LIGHT KIT MOUNTING PLATE...................... 8 PACKAGE CONTENTS..................................................................... 2 INSTALLING THE LIGHT PLATE......................................................... 9 INSTALLING THE FAN.....................................................................3 INSTALLING THE LIGHT BULB & GLASS SHADE ......................
1 SAFETY RULES 1. Before you begin installing the fan, shut power off at the circuit breaker of the fuse box. 2. Be cautious! Read all instructions and safety information before installing your new fan. Review accompanying assembly diagrams. 3. Make sure that all electrical connections comply with local codes, ordinances, or National Electrical Codes. Hire a qualified electrician or consult a do-it-yourself wiring handbook if you are unfamiliar with installing electrical wiring. 4.
ATTENTION: The Energy Policy Act of 2005 requires this fan to be equipped with a 190 watt limiting device. If lamping exceeds 190 watts, the ceiling fan's light kit will shut off automatically. NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors which can not be built into this product.
2 PACKAGE CONTENTS 3 Unpack your fan and check the contents. You should have the following items: 1. Fan blades (4) 2. Blade support plates (4) 3. Hanger bracket 4. Canopy 5. Canopy cover 6a. Standard downrod assembly 6b. Minimum-length downrod (for close to ceiling mounting only) 7. Coupling cover 8. Fan motor/housing assembly 9. Light kit mounting plate 10. Light plate 11. Glass shade 12. Optional aluminum cover 13. Receiver (includes 6 wire nuts) 14. Hand held remote with 2 Screws 10 4 15.
Tools Required: Phillips screw driver; slotted screw driver; step-ladder; wire cutters; electrical tape. MOUNTING OPTIONS If there isn't an existing mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers. Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials. The outlet box and its support must be able to fully support the moving weight of the fan (at least 50 lbs.).
4 BLADE INSTALLATION Step 1. (Fig. 5) Remove the metal plate and upper cover by remove the screws from the motor. Step 2. (Fig. 6) Insert the blade through the access window from the blade holder. Align holes from the blade and motor and secure with screws with lock washers and blade support plate. Repeat process with the other blades. Step 3. (Fig. 7) Replace the upper cover and the metal plate to the motor and secure with the screws previously removed.
HANGING THE FAN WARNING: All of the parts, hardware and components such as the hanger bracket and hanger ball have been provided for your safety and the proper installation of your new ceiling fan. The use of other parts, hardware or components not supplied by Minka Aire® with the fan will void the Minka Aire® Warranty. Step 4. Carefully feed fan wires up through the downrod. (Fig.
DOWNROD RUBBER COVER DOWNROD OUTLET BOX CROSS PIN DOWNROD SET SCREWS HITCH PIN LOCK PIN HANGER BALL SET SCREW COUPLING *OMIT COUPLING COVER WHEN THE MINIMUM-LENGTH DOWNROD SUPPLY WIRES CANOPY CANOPY COVER SET SCREWS REGISTRATION SLOT DOWNROD HANGER BRACKET Fig. 8 Fig. 9 Fig. 10 Fig. 11 LOCK PIN Fig. 12 HITCH PIN Fig.
ELECTRICAL CONNECTIONS WARNING:: To avoid possible electrical shock be sure electricity is turned off at the main fuse or breaker box before wiring. NOTE: The Aire Control® System is equipped with a learning frequency function which has 256 code combinations to prevent potential interference from other remote units. The frequency on your Receiver and Transmitter units have been preset at the factory. (Fig.
Step 3. Receiver to House Supply Wires Electrical Connections: Connect the WHITE wire (Neutral) from the outlet box to the WHITE wire marked "AC in N" from the receiver. Connect the BLACK wire (Hot) from the outlet box to the BLACK wire marked "AC in L" from the receiver. Secure all wire connections with the plastic wire nuts provided. (Fig. 16) Step 4. If your outlet box has a GROUND wire (Green or Bare Copper) connect this wire to the Hanger Ball and Hanger Bracket Ground wires.
OUTLET BOX BLACK (HOT) BLACK ("AC IN L") WHITE (NEUTRAL) GREEN OR BARE COPPER (GROUND) WHITE ("AC IN N") RECEIVER BLACK ("TO MOTOR L") BLUE (FOR LIGHT) ORANGE (FOR UPPER LIGHT) BLUE (FOR LIGHT) BLACK (MOTOR) ORANGE (FOR UPPER LIGHT) Fig. 16 WHITE ("TO MOTOR N") GROUND- (CONNECT TO (GREEN) GROUND WIRE ON HANGER BRACKE IF NO HOUSE GROUND WIRE EXISTS.
7 FINISHING THE INSTALLATION Step 1. Remove 1 of the 2 screws from the bottom of the hanger bracket and loosen the other one half a turn from the screw head. Step 2. Slide the canopy up towards the hanger bracket and place the key hole on the canopy over the screw on the hanger bracket, turn canopy until it locks in place at the narrow section of the key holes. (Fig. 17) OUTLET BOX HANGER BRACKET HANGER BALL Step 3.
8 INSTALLING THE LIGHT KIT MOUNTING PLATE Step 1. Remove 1 of 3 screws from the mounting ring and loosen the other 2 screws. (Do not remove) Step 2. Place the key holes from the light kit mounting plate over the 2 screws previously loosened from the mounting ring, turn Light kit mounting plate until it locks in place at the narrow section of the key holes. Secure by tightening the 2 screws previously loosened and the one previously removed. (Fig. 18) MOUNTING RING LIGHT KIT MOUNTING PLATE Fig.
9 INSTALLING THE LIGHT PLATE NOTE: Before starting installation, make sure power is turned off at the circuit breaker. 1. Remove 1 of 3 screws from the light kit mounting plate and loosen the other 2 screws. (Do not remove) 2. Raise and hold the light plate close to the light kit mounting plate and proceed to do the wire connections. Connect the white wire connectors from the light plate and fan, follow the same procedure with the black wire connectors. (Fig. 19) 3.
INSTALLING THE LIGHT BULB & GLASS SHADE WARNING: Shut of the power supply before removing or replacing lamp. In handling of halogen bulb, care should be taken not to touch it with your bare hands. Oil residue will shorten the life of the halogen bulb. If you accidentally come into contact, wipe thoroughly with a clean, lint-free, cotton cloth. Allow the bulb to cool off for 10 minutes before changing the bulb. Use light bulb in accordance with the fan's specification.
BULB GLASS SHADE Fig 20 MOUNTING PLATE MOUNTING PLATE ALUMINUM COVER Fig 21
OPERATING THE REMOTE CONTROL/WALL CONTROL Remote Control only: Install a A23 12 volt battery (included). To prevent damage to transmitter remove the battery if not used for long periods of time. instructions apply to ceiling fans that feature a DOWN D. OFF-ON Slide Button (Wall Control Fans Only) light ( button) only or ceiling fans that feature an UP This button turns the power Off and On to the Fan and A. Buttons: light ( button) and a DOWN light ( button) that are Light(s).
Speed settings for warm or cold weather depend on factors such as room size, ceiling height and number of fans. NOTE: Wait for the fan to stop before reversing the direction of the blade rotation. Warm Weather (forward) A DOWNWARD airflow creates a cooling effect as shown in Figure 22. This allows you to set your air conditioner on a warmer setting without affecting your comfort. Cool Weather (Reverse) An UPWARD airflow moves warmer air off the ceiling area as shown in Figure 23.
CARE OF YOUR FAN Here are some suggestions to help maintain your fan. 1. Because of the fan's natural movement some connections may become loose. Check the support connections, brackets and blade attachments twice a year. Make sure they are secure. (It is not necessary to remove fan from the ceiling). 2. Clean your fan periodically to help maintain its new appearance over the years. Use only a soft brush or lint free cloth to avoid scratching the finish.
13 TROUBLESHOOTING SYMPTOM Fan will not start SOLUTION Check to make sure the wall switch is turned on. SYMPTOM Fan Sounds Noisy SOLUTION Allow a 24-hour "break in" period. Most noises associated with a new fan will go away during this time. Check circuit fuses or breakers. Caution! Make sure the power is turned off before performing the following steps. Remove canopy and check wire connections. Check wall control transmitter connections (if applicable).
SYMPTOM Fan Wobble SOLUTION NOTE: All blade sets are grouped by weight. Because wood and plastic blades vary in density, the fan may wobble even though blades are matched. Make sure outlet box is secured to building structure, if necessary use the wood screws provided to further secure outlet box to joist. Make sure hanger bracket is secure to the outlet box, screws are tight. If a Balancing kit is provided follow the instructions included with the balancing kit to help correct any excessive wobble.
SYMPTOM Frequency Interference SOLUTION 1. Turn the power off to your ceiling fan. 2. Please use a small size tool to change the frequency settings on the control system. 3. Return power to the unit. Note: After the AC power is on, do not press any other button on the transmitter before pressing the "Stop" button, doing so will cause the procedure to fail. 4. Within 60 seconds of turning the Fan's AC power ON. Press the transmitter's "Stop" button and hold the "Stop¡" button for 10 seconds. 5.
14 SPECIFICATIONS These are typical readings. Your actual fan may vary. They do not include amps and wattage used by the light(s). Fan Size Speed 52" Low Medium High Volts Amps Watts RPM CFM 120 120 120 0.28 0.37 0.46 12.8 25.8 49.9 65 103 150 N.W. 2,037 8.30 3,042 Kgs 4,617 For any additional information about your Minka Aire Ceiling fan, please write to; R 1151 W. Bradford Court, Corona, CA 92882 For Customer Assistance Call: 1-800-307-3267 G.W. C.F. 9.42 Kgs 1.