User manual
15
Reading the Advanced Variables
Reading these variables is done by entering
0-111 according to the programming button
hence
Address 00
Max. speed 1
Delay 1
Pulse width 1
Stop section 1
and pressing the programming button.
Writing the Advanced Variable
Note:
2 stop sections must always be set in order to program the
advanced variables!
Writing these values is done by entering
00 = VAI according to the programming button
hence
Address 00
Max. speed V (Velo)
Delay A (Acce)
Pulse width I (Impw)
Stop section 2 (Stop)
and pressing the programming button.
The values to be entered for the VAI are explained in the
following:
Note:
If the motor “whistles” after being placed into operation,
then you probably forgot to enter the standard values again.
Swapping Connections (Velo)
If you should have swapped the connections on open
decoder wiring, you can “adjust” this electronically. First
check which connections need to be swapped, and then
enter as a value the number that can be taken from the
following table:
Motor Light Track Number
x x – 7
– x – 6
x – – 5
– – – 4 (standard)
x x x 3
– x x 2
x – x 1
– – x 0
Note:
Swapping the connections for the motor or the track will
lead to corresponding changes in analog operation.