User manual
PRELIMINARY
miniDSP Ltd, Hong Kong / www.minidsp.com / Features and specifications subject to change without prior notice 22
3.5 RUNNING THE MEASUREMENTS
Measurements are performed on the Measurements screen.
3.5.1 Listening environment
The Dirac Live Calibration Tool For miniDSP presents two different listening environments as a visual guide to
positioning the microphone for each measurement: Chair, for a single listening seat, and Sofa, for multiple
listening seats. Select a listening environment by clicking on the chosen icon.
The center of the screen contains a pictorial representation of the selected listening environment, with dots
marking the microphone locations. Completed measurements are shown in green, while the next measurement
to be done is highlighted in yellow and has a red arrow marker pointing to it. A drop-down menu underneath
selects three different views, which should be used to help you place the microphone in the correct location.