Computer Accessories User Manual

SMARTRACK 116 IP
55
Note! Picture quality is relative to distance. The further away a remote computer is
from the SmartRack 116 IP, the lower the image quality, and the more tuning
needed. So place the higher resolution computers closer to the manager unit.
24.1.13 Moving the label F6
Position the OSD label anywhere on the screen.
To position the label from the Main window:
1. Navigate to the desired computer using the Up and Down arrow keys.
2. Press F6. The selected screen image and Identification label appears.
3. Use the arrow keys to move the label to the desired position.
4. Press Esc to save and exit.
24.1.14 DDC F10
Display Data Channel (DDC) is a VESA standard for communication between a
monitor and a video adapter.
Input the DDC information of the monitor connected to the SmartRack 116 IP
switch into the memories of all connected ROCs when first installing system.
To input the DDC information:
1. Press Shift twice to open the OSD.
2. Press F10. Please wait flashes a few times and disappears. The monitors
DDC information is sent to all ROCs.
24.1.14.1 Updating the DDC information
Update the DDC information in any of the following circumstances:
When replacing the monitor connected to SmartRack 116 IP Switch
When adding a new ROC to the system
When reconnecting an existing ROC that was temporarily used in a
different system
To update the DDC information, repeat the steps as set out above.