User`s guide

The Manager unit
8-10
5UM20044
Version 10400
Jumper
JP7
Figure 8-7 Jumper JP7
3. Reinsert the
Manager
card, close the cover, and
reconnect the power cord.
4. Switch on the computer. Damage to the
Phantom
firmware prevents you from displaying the OSD.
5. Start the
Phantom
Update
program, and carry out
the download process again. Where you were
updating the OSD
AND
the
Manager
firmware, you
must first update the OSD.
Since Jumper
JP7
is closed the
Phantom Update
program does not show the firmware version number
after completing the download.
6. Switch off the
Phantom
Manager
computer and
disconnect the power cord.
7. Open the cover, extract the
Phantom
Manager
card
and open Jumper
JP7
.
8. Reinsert the
Manager
card, close the cover, and
reconnect the power cord.
9. Check the OSD and make sure the system functions
properly.