User`s guide
The Box Version
3-4
5UM20044
Version 10400
Setting the Slave unit’s ID Number
You set the
Slave
unit’s
ID Number by adjusting the
Dipswitches. The Dipswitches of the
Box
version are
located on the underside of the box. The Dipswitches
of the
Card
version are located as illustrated in Figure
3-2 on page 3-2.
Set the ID Number on each Unit using Dipswitches 1
to 6. See Figure 3-5.
8
OFF
ON
ID NUMBER
1234567
Figure 3-5 Setting the ID Number
The ID Numbers are set using binary numbers.
OFF
= 0,
ON
= 1.
See the binary table on page 3-5 below.
Caution!
Do not set the identical ID Number for two
units.
Dipswitches 7 and 8 are inactive and should always be
set to the
OFF
position.
The Manager unit’s ID Number
The
Manager
unit comes preset to ID Number 1, and
appears listed in the OSD window as:
1 PHANTOM MANAGER