Operating the Smart 216/232 IP Switching System Locally
Configuring the OSD Settings (F2)
User Guide | 83
When first installing the system, emulate the DDC information of the monitor
connected to the Smart 216/232 IP switch into the memories of all connected ROCs.
To input the DDC information:
1. From the OSD Settings window (see Figure 66), press F10.
“Please wait” flashes a few times and disappears.
The monitor’s DDC information
is sent to all ROCs.
You should update the DDC information in any of the following circumstances:
When replacing the monitor connected to Smart 216/232 IP Switch
When adding a new ROC to the system
When reconnecting an existing ROC that was temporarily used in a different
system
To update the DDC information, follow the steps in the procedure for inputting DCC
information.
7.7.5 Saving Changes to Settings
To save changes to the settings:
1. In the OSD Settings window (see Figure 66), press Esc.
Setti
ngs are saved. The OSD Main window appears (see Figure 62).