Installation
DIP Switch Setup
Before installing the camera, set up the DIP switch to configure the camera ID and the communication protocol.
Figure 2-1 Location of DIP Switch
Camera ID Setup
z ID numbers of cameras are set up with binary numbers. See the
examples shown below.
Table 2-1 Example of Camera ID Setup
Pin 1 2 3 4 5 6 7 8
Digit Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7
Binary Value 1 2 4 8 16 32 64 128
ex) DIP Switch
Value=5
ON OFF ON OFF OFF OFF OFF OFF
ex) DIP Switch
Value =10
OFF ON OFF ON OFF OFF OFF OFF
Pelco-D Camera ID = DIP Switch Value