User's Manual

Personal Node User Manual Section 4 Working with the Personal Node
Rev: 1.1 15 / 70
© Minetec 2019
Table 4 Basic default alarms
Zone/Function
Radius (m)
LED colour
LED cycle
LED repeat
Audio (Hz)
Audio cycle
Audio repeat
ALERT
Disabled
N/A
N/A
N/A
None
N/A
No
ALARM
100
Yellow
Flash every
two seconds
Yes
2000
Beep in sync
with LED
No
SLOW
50
Orange
Flash once
per second
Yes
2000
Beep in sync
with LED
No
STOP
20
Red
Flash twice
per second
Yes
2000
Beep in sync
with LED
Yes
IVD zone detected
Defined by vehicle
setup.
Red
Solid
N/A
2000
Constant tone
N/A
IVD
2
zone activated
Within vehicle offset.
Refer Fleet map.
Green
Solid
N/A
No
No
N/A
Broadcast Me
Any range
White
Flash once
per second
Yes
500
1 beep per
second
Yes
As part of a start-up check, the audible alarm also annunciates for a few seconds when removing the Personal Node from the charging dock. For more
details on the audible alarms, see About patterns on page 22.
Patterns are Site specific and are factory configurable.
2
Note that the STOP alarm annunciates when a Personal Node exits the IVD zone.