Installation Guide
Page 8
The RC-50 unit will automatically detect 110 or 220VAC and no internal adjustments are required.
When choosing a power source, choose a source that turns on and off with the pump motor.
It is very important that the unit turn off when there is no water owing past the electrodes. The ideal source is
the timer box. If no timer box exists, the unit can use the pump motor as its power source.
ATTENTION:
YOU MUST FOLLOW ALL APPLICABLE LOCAL, STATE, NATIONAL,
OR INTERNATIONAL CODES WHEN INSTALLING THIS EQUIPMENT. A
CERTIFIED ELECTRICIAN MAY BE REQUIRED FOR THIS PART OF THE
INSTALLATION.
Choosing a power source
E.) Installing the Unit (Continued)
6.) Seat the “O” ring in the electrode jar and hand tighten onto the black ow-cell chamber, no Teon tape or wrench
required!
Mounting the Control Box
Keep the protective clear plastic sheet on during installation to stay clear of
scratching the unit.
1.) Install the four mounting brackets using the enclosed screws to the back of
the control box.