Installation Guide
Page 12
E.) Installing the Unit (Continued)
PVC, CPVC, or PEX PIPE INSTRUCTIONS
1.) Insert the pre-stripped end of the signal cable into one of the two signal terminals and tighten.
2.) Route the signal cable to the inlet pipe. Hold cable parallel and next to the pipe.
3.) Wrap one of the cable ties tightly so that the signal cable is secured to the pipe. (Figure A)
4.) Wrap the loose end of the signal cable securely around the pipe - in any one direction.
Wrap the pipe until you reach 40 wraps.
5.) Make sure the wraps are ush against one other, wrapped tightly and not overlapping.
6.) Wrap a second cable tie at the end of the wrappings securing the signal cable tightly. (Figure B)
7.) Route the loose end of the signal cable back to the power box. Trim excess cable to length.
8.) Carefully strip the outer plastic shield form the end of the signal cable leaving 1/4” to 3/8” of bare cable.
Twist the bare cable and insert the end in the other terminal post on the power box and tighten the receptacle
post.
Wrapping the pipe with the ScaleBlaster signal cable