Full Product Manual
Page 9
E.) Installing the Unit (Continued)
Mounting the Control Box (continued)
2.) Install the four mounting brackets using the enclosed screws to the back of the control box. Mount the
control box to the wall allowing for the electrode and coil wire to reach prospective locations. Remember the
ScaleBlaster wire has to reach the area of the pipe where the coil will go and return back to the control box.
Hold the control box up to the wall or surface to where it will be mounted and mark the four screw holes. Using
a bullet level will ensure the control box is straight. Attach the control box to the wall according to the wall
material using approved mounting hardware for that material, i.e. wood screws, mollys, concrete screws, or
anchors.
Installing the K-Flex Conduit
3.) The control box in equipped with a k-flex conduit connector for attaching to the electrical power source.
Run conduit to the control box either from the pump motor or timer box, we recommend using the timer box.
Please refer to the conduit manufacturer's instructions, your local state building codes, and electrical codes for
the details on proper installation of the k-flex conduit.