A.) IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed,
including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. For Model: RC-50
WARNING
To reduce the risk of injury, do not permit children to use this product unless they are closely supervised
at all times.
3. For all permanently-installed units intended for use on 15 or 20 ampere, 125 through 240 volt, single phase
branch circuits
WARNING - Risk of Electric Shock.
Connect only to a branch circuit protected by a ground-fault circuit-interrupter (GFCI). Contact a
qualified electrician if you cannot verify that the circuit is protected by a GFCI.
4. (For all permanently installed units intended for use on 15 or 20 ampere, 125 through 240 volt, single phase
branch circuits.)
The unit must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter
(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the
GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be
restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to
the unit without the test button being pushed, a ground current is flowing, indicating the possibility of an
electric shock. Do not use this unit. Disconnect the unit and have the problem corrected by a qualified
service representative before using.
5. SAVE THESE INSTRUCTIONS.
6. (only on metal enclosures)
A wire connector is provided on this unit to connect a minimum No. 8 AWG (8.4 mm²) solid copper conductor
between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or
conduit within 5 feet (1.5 m) of the unit.
7. DANGER - Risk of electric shock.
Install at least 5 feet (1.5 m) from all metal surfaces. As an alternative, a spa may be installed within 5 feet
of metal surfaces, if each metal surface is permanently connected by a minimum No. 8 AWG (8.4
mm²) solid copper conductor to the wire connector on the terminal box that is provided for this
purpose.