E.) Installing the Unit
(Continued)
Connecting the timer box to the control box
4.) Below is an example of connecting the control box to a timer box. In this example an Intermatictm timer
box is used. Although most timer boxes are similar they are not exactly the same, please take care when using
the provided information.
230 VAC Operation:
Connect the black (3 stranded) wire cable to the 230 VAC timer box by splicing
the 3 wires and connecting the black and white wires to the LOAD side on the
timer box. It makes no difference which colored wire goes to the two load screws.
Connect the green wire to GROUND. When installed properly, the unit should
come on and off when the pool pump goes on and off.
115 VAC Operation:
Connect either the white wire or the black wire to the LOAD side on the timer box. It
makes no difference which colored wire goes to the two load screws. Connect the
green wire to ground. When installed properly, the unit should come on and off when
the pool pump goes on and off.
Connecting the pump motor to the control box
5.) Disconnect the back plate to the motor where the electrical
connections are. You will notice two connections where the
power source comes in and is connected. Connect the
MineralPURE's power cable (black, white and green) to the
same as the motor's connections. If connected properly, the
unit should come on and off with the motor.