User Manual
Table Of Contents
- 08-0308 - Manual Cover.pdf
- 0070-10-0690-01 Panorama Operations Maual with Telepack 2.4 - CH16 REVISED2.pdf
- Foreword
- Warnings, Precautions and Notes
- Indications for Use
- Unpacking Information
- Symbols and Descriptions
- Technical Support
- 1.0 System Overview
- 1.1 Components of the Panorama System
- 1.2 Licensing Key
- 1.3 Supported Devices
- 1.3.1 Panorama Central Station
- 1.3.2 Panorama ViewStation and WorkStation
- 1.3.3 Panorama Telemetry Server
- 1.3.4 Panorama Wireless Transceiver
- 1.3.5 Panorama Gateway
- 1.3.6 Panorama Web Viewer
- 1.3.7 Passport 2® Bedside Monitor
- 1.3.8 Spectrum™ Bedside Monitor
- 1.3.9 Spectrum OR™ Bedside Monitor
- 1.3.10 Panorama Telepack
- 1.3.11 Network Printer
- 1.4 Troubleshooting
- 2.0 Getting Started
- 3.0 Alarm Behavior
- 4.0 Arrhythmia and ST Analysis
- 5.0 Patient Setup Functions
- 5.1 Demographics Tab
- 5.2 Transfer Tab
- 5.3 Discharge Tab
- 5.4 Display Tab
- 5.5 Standby Tab
- 5.6 Wave Gain Tab (Patient)
- 5.7 Print Setup Tab (Patient)
- 6.0 Patient Alarm Functions
- 7.0 Views
- 7.1 Bedside Tab
- 7.2 Trends Tab
- 7.3 Events Tab
- 7.4 Disclosure Tab
- 7.4.1 Accessing the Disclosure Tab
- 7.4.2 Disclosure Tab (Waveforms View)
- 7.4.2.1 Accessing the Waveforms View
- 7.4.2.2 Components of the Waveforms View
- 7.4.2.3 Navigating in the Waveforms View of the Disclosure Tab
- 7.4.2.4 ST Button
- 7.4.2.5 Comments Dialog Box (Optional)
- 7.4.2.6 Sidebar Buttons
- 7.4.2.7 Printing a Full Disclosure Zoom In Report from the Waveforms View
- 7.4.2.8 Troubleshooting
- 7.5 ST Tab
- 8.0 Report Functions
- 8.1 Patient Reports Tab
- 8.2 System Reports Tab
- 8.3 Print Status Tab
- 8.4 Additional Reports
- 9.0 System Setup Functions
- 9.1 Parameter Color Tab
- 9.2 Touch Screen Tab
- 9.3 Installation Setup Tab
- 9.4 Care Group Tab
- 9.5 Volume Tab
- 9.6 System Alarms Tab
- 9.7 Passwords Tab
- 9.8 Equipment Setup Tab
- 9.9 More Tab
- 9.10 Previous Tab
- 9.11 Date/Time Tab
- 9.12 Print Setup Tab (System)
- 9.13 Unit Priorities Tab
- 9.14 Unit Choices Tab
- 9.15 Wave Gain Tab (System)
- 9.16 Wireless Tab
- 10.0 Telepack (Optional)
- 11.0 User Maintenance
- 12.0 Parameter Specifications
- 12.1 Parameter Specifications
- 12.1.1 Heart Rate: HR
- 12.1.2 Respiration: Resp
- 12.1.3 NIBP
- 12.1.4 SpO2
- 12.1.5 Nonin SpO2
- 12.1.6 IBP: mmHg
- 12.1.7 CO2
- 12.1.8 O2
- 12.1.9 INSP/ET O2
- 12.1.10 N2O
- 12.1.11 Anesthetic Agents: Iso, Enf, Des, Sev, Hal, Agent
- 12.1.12 Premature Ventricular Contraction (PVC)
- 12.1.13 Temp: T1,T2, Delta T, and T Blood
- 12.1.14 ST
- 12.1.15 Cardiac Output
- 12.1.16 Cardiac Index
- 12.1.17 Pulmonary Artery Wedge Pressure (PAWP)
- 12.1.18 Battery Percentage
- 12.2 Invalid Data Display
- 12.1 Parameter Specifications
- 13.0 Alarms and Events
- 14.0 Network Tab (Optional)
- 14.1 Network Tab
- 14.1.1 Accessing the Network Tab
- 14.1.2 Sorting the Contents of the Network Tab List Box
- 14.1.3 Assigning Patient Tiles in the Network Tab
- 14.1.4 Removing a Patient Tile Assignment in the Network Tab
- 14.1.5 Removing All Patient Tile Assignments in the Network Tab
- 14.1.6 Refreshing the Network Tab List Box
- 14.1.7 Troubleshooting
- 14.1 Network Tab
- 15.0 Paging Tab (Optional)
- 15.1 Paging Password Tab
- 15.2 Paging Tab
- 15.2.1 Accessing the Paging Tab
- 15.2.2 Adding a Pager
- 15.2.3 Assigning a Patient Tile
- 15.2.4 Adding All Patient Tiles to a Pager
- 15.2.5 Removing a Patient Tile Assignment
- 15.2.6 Removing All Patient Tiles from a Pager
- 15.2.7 Editing a Pager
- 15.2.8 Removing a Pager
- 15.2.9 Resending a Failed Page
- 15.2.10 Generating a Paging Report
- 15.2.11 Troubleshooting
- 17.0 Glossary
Panorama™ Operating Instructions 0070-10-0690-01 4 - 17
Arrhythmia and ST Analysis Arrhythmia Alarms
NOTE: The Pause alarm is only available when using a View 12
™
card.
The Pause alarm has priority settings of 1, 2, 3, and OFF. When the setting is:
•Set to 1, the Panorama Central Station produces an Alarm Priority 1 sound once the
condition is identified.
•Set to 2, the Panorama Central Station produces an Alarm Priority 2 sound once the
condition is identified.
•Set to 3, the Panorama Central Station produces an Alarm Priority 3 sound once the
condition is identified.
•Set to OFF, the Panorama Central Station does not produce any audio alarm indicators
for the Pause alarm condition.
• The Pause alarm causes a Pause text message to display in the Patient Status line. The
color of the message is dependant on the configured alarm priority.
PVC/minute Alarm
The High PVC alarm is activated at the Panorama Central Station when the number of PVCs
detected per minute exceeds the configured threshold. The PVC rate alarm can be set to Off,
or 1 to 30 PVCs per minute.
NOTE: The PVC/min counter will be set to invalid and display (---)
when Asystole, V-Tach, V-Fib, or V-Rhythm is detected.
The High PVC alarm has priority settings of 2, 3, and OFF. When the setting is:
•Set to 2, the Panorama Central Station produces an Alarm Priority 2 sound once the
condition is identified.
•Set to 3, the Panorama Central Station produces an Alarm Priority 3 sound once the
condition is identified.
•Set to OFF, the Panorama Central Station does not produce any audio alarm indicators
for the High PVC alarm condition.
• The High PVC alarm causes a yellow High PVC text message to display in the Patient
Status line.
Run Alarm
The Run alarm is activated at the Panorama Central Station when the number of consecutive
PVCs occur at a rate that exceeds the user defined V-Tach rate from 3 beats in a row to one
beat less than the user defined V-Tach threshold. For additional information about V-Tach,
refer to the definition for ‘‘Ventricular Tachycardia (V-Tach) Alarm’’ on page 4-15.
The Run alarm has priority settings of 2, 3, and OFF. When the setting is:
•Set to 2, the Panorama Central Station produces an Alarm Priority 2 sound once the
condition is identified.
•Set to 3, the Panorama Central Station produces an Alarm Priority 3 sound once the
condition is identified.
•Set to OFF, the Panorama Central Station does not produce any audio alarm indicators
for the Run alarm condition.
• The Run alarm causes a yellow Run text message to display in the Patient Status line.