User Manual
Table Of Contents
- 08-0308 - Manual Cover.pdf
- 0070-10-0690-01 Panorama Operations Maual with Telepack 2.4 - CH16 REVISED2.pdf
- Foreword
- Warnings, Precautions and Notes
- Indications for Use
- Unpacking Information
- Symbols and Descriptions
- Technical Support
- 1.0 System Overview
- 1.1 Components of the Panorama System
- 1.2 Licensing Key
- 1.3 Supported Devices
- 1.3.1 Panorama Central Station
- 1.3.2 Panorama ViewStation and WorkStation
- 1.3.3 Panorama Telemetry Server
- 1.3.4 Panorama Wireless Transceiver
- 1.3.5 Panorama Gateway
- 1.3.6 Panorama Web Viewer
- 1.3.7 Passport 2® Bedside Monitor
- 1.3.8 Spectrum™ Bedside Monitor
- 1.3.9 Spectrum OR™ Bedside Monitor
- 1.3.10 Panorama Telepack
- 1.3.11 Network Printer
- 1.4 Troubleshooting
- 2.0 Getting Started
- 3.0 Alarm Behavior
- 4.0 Arrhythmia and ST Analysis
- 5.0 Patient Setup Functions
- 5.1 Demographics Tab
- 5.2 Transfer Tab
- 5.3 Discharge Tab
- 5.4 Display Tab
- 5.5 Standby Tab
- 5.6 Wave Gain Tab (Patient)
- 5.7 Print Setup Tab (Patient)
- 6.0 Patient Alarm Functions
- 7.0 Views
- 7.1 Bedside Tab
- 7.2 Trends Tab
- 7.3 Events Tab
- 7.4 Disclosure Tab
- 7.4.1 Accessing the Disclosure Tab
- 7.4.2 Disclosure Tab (Waveforms View)
- 7.4.2.1 Accessing the Waveforms View
- 7.4.2.2 Components of the Waveforms View
- 7.4.2.3 Navigating in the Waveforms View of the Disclosure Tab
- 7.4.2.4 ST Button
- 7.4.2.5 Comments Dialog Box (Optional)
- 7.4.2.6 Sidebar Buttons
- 7.4.2.7 Printing a Full Disclosure Zoom In Report from the Waveforms View
- 7.4.2.8 Troubleshooting
- 7.5 ST Tab
- 8.0 Report Functions
- 8.1 Patient Reports Tab
- 8.2 System Reports Tab
- 8.3 Print Status Tab
- 8.4 Additional Reports
- 9.0 System Setup Functions
- 9.1 Parameter Color Tab
- 9.2 Touch Screen Tab
- 9.3 Installation Setup Tab
- 9.4 Care Group Tab
- 9.5 Volume Tab
- 9.6 System Alarms Tab
- 9.7 Passwords Tab
- 9.8 Equipment Setup Tab
- 9.9 More Tab
- 9.10 Previous Tab
- 9.11 Date/Time Tab
- 9.12 Print Setup Tab (System)
- 9.13 Unit Priorities Tab
- 9.14 Unit Choices Tab
- 9.15 Wave Gain Tab (System)
- 9.16 Wireless Tab
- 10.0 Telepack (Optional)
- 11.0 User Maintenance
- 12.0 Parameter Specifications
- 12.1 Parameter Specifications
- 12.1.1 Heart Rate: HR
- 12.1.2 Respiration: Resp
- 12.1.3 NIBP
- 12.1.4 SpO2
- 12.1.5 Nonin SpO2
- 12.1.6 IBP: mmHg
- 12.1.7 CO2
- 12.1.8 O2
- 12.1.9 INSP/ET O2
- 12.1.10 N2O
- 12.1.11 Anesthetic Agents: Iso, Enf, Des, Sev, Hal, Agent
- 12.1.12 Premature Ventricular Contraction (PVC)
- 12.1.13 Temp: T1,T2, Delta T, and T Blood
- 12.1.14 ST
- 12.1.15 Cardiac Output
- 12.1.16 Cardiac Index
- 12.1.17 Pulmonary Artery Wedge Pressure (PAWP)
- 12.1.18 Battery Percentage
- 12.2 Invalid Data Display
- 12.1 Parameter Specifications
- 13.0 Alarms and Events
- 14.0 Network Tab (Optional)
- 14.1 Network Tab
- 14.1.1 Accessing the Network Tab
- 14.1.2 Sorting the Contents of the Network Tab List Box
- 14.1.3 Assigning Patient Tiles in the Network Tab
- 14.1.4 Removing a Patient Tile Assignment in the Network Tab
- 14.1.5 Removing All Patient Tile Assignments in the Network Tab
- 14.1.6 Refreshing the Network Tab List Box
- 14.1.7 Troubleshooting
- 14.1 Network Tab
- 15.0 Paging Tab (Optional)
- 15.1 Paging Password Tab
- 15.2 Paging Tab
- 15.2.1 Accessing the Paging Tab
- 15.2.2 Adding a Pager
- 15.2.3 Assigning a Patient Tile
- 15.2.4 Adding All Patient Tiles to a Pager
- 15.2.5 Removing a Patient Tile Assignment
- 15.2.6 Removing All Patient Tiles from a Pager
- 15.2.7 Editing a Pager
- 15.2.8 Removing a Pager
- 15.2.9 Resending a Failed Page
- 15.2.10 Generating a Paging Report
- 15.2.11 Troubleshooting
- 17.0 Glossary
LED Indicator Lights Telepack (Optional)
10 - 6 0070-10-0690-01 Panorama™ Operating Instructions
NOTE: If a 3-wire Lead set is used, a maximum of three lights will
illuminate. If a 5-wire Lead set is used, a maximum of five
lights will illuminate.
10.3.2 Link Status LED Indicator Light
The Telepack Link Status LED indicator light verifies the Telepack’s connection to the
Panorama Patient Monitoring Network.
The Link Status LED indicator light remains on for approximately 10 seconds during the initial
power up and during the test sequence.
Press the CHECK button to verify the Telepack’s link status with the wireless network. The
Telepack’s Link Status LED indicator light shows the results of the link status test:
• Link Status LED Indicator Light (Telepack-2.4):
On — Connection to the Panorama Central Station is successful.
Off — Connection to the Panorama Central Station is unsuccessful. Telepack may be out
of range from an access point to the Panorama Central Station, or the battery may need
to be replaced.
Flashing — Attempting to connect to the Panorama Central Station.
• Link Status LED Indicator Light (Telepack-608):
On — Telepack is within range of the Panorama wireless network.
Off — Telepack is out of range of the Panorama wireless network, or the battery may
need to be replaced.
NOTE: When the CHECK button is pressed, all of the device LED
indicator lights are tested simultaneously.
10.3.3 Battery Status LED Indicator Light
The Telepack Battery Status LED indicator light verifies the status of the Telepack’s batteries.
Press the CHECK button to verify the Telepack’s battery status.
NOTE: When the CHECK button is pressed, all of the device LED
indicator lights are tested simultaneously.
During this test sequence, the Battery Status LED indicator light will remain on for
approximately 10 seconds if the Telepack batteries have more than 2 hours of battery life
remaining. A flashing Battery Status LED light indicates the Telepack batteries have less than
2 hours of battery life remaining. An unlit Battery Status LED light indicates the Telepack
batteries should be replaced immediately, or that they have been incorrectly inserted.
NOTE: The Telepack device should not be used for battery storage
purposes.
NOTE: When a Telepack is assigned to a patient tile, the battery
charge percentage integer, and percent sign (%) are
displayed in the digital data tile at the central station.
NOTE: The Telepack batteries used may be subject to local
regulations regarding disposal. At the end of the battery
life, never dispose of the batteries in a fire. Batteries should
be disposed of in accordance with any local regulations.