8.2.4 Electrical Characteristics
Parameter
Conditions
Min
Typical
Max
Units
Power supply
Input voltage
Normal operation
10.5
60
V
Power Consumption
Idle, Tx off
5.5
7.6
W
Power Consumption
Tx Active
20
26
W
Ethernet
Tx Peak Differential
voltage
100Base-Tx, 100 Ohm
termination
1.00
1.05
V
Tx voltage imbalance
100Base-Tx, 100 Ohm
termination
2
%
Tx Rise/Fall time
100Base-Tx
3
5
ns
Tx Rise/Fall imbalance
100Base-Tx
0
0.5
ns
Tx duty cycle distortion
100Base-Tx
+/- 0.5
ns
Tx Overshoot
100Base-Tx
5
%
Tx Output Jitter
100Base-Tx, Peak to
Peak
0.7
1.4
ns
Tx Peak Differential
voltage
10Base-T, 100 Ohm
termination
2.4
V
Tx Output Jitter
10Base-T, Peak to Peak
1.4
11
ns
Rx Squelch Threshold
10Base-T, 5MHz square
wave
400
mV
Serial
Output Voltage swing
Loaded with 3kOhms to
ground
+/- 5
+/- 5.4
V
Output short circuit
current
-60
+60
mA
Input Voltage
-25
+25
V
Input Low Threshold
Temperature ambient =
+25
0.8
1.5
V
Input High Threshold
Temperature ambient =
+25
1.8
2.4
V
5VPC Output Current 200 200 mA
GPIO
Input voltage
Input
-0.3
60
V
Current Sinking
Capability
Output driving low
100
mA
Input Impedance
109
kOhms
Alarm
Input current (max)
300
mA