8. Click Read in the CCMS page.
9. Click Calculate in the CCMS page.
10. Click Save in the CCMS page.
11. Connect signal generator via a 30dB attenuator to Channel 2 receiver.
12. Repeat Step 2 to 10 for the Channel 2 receiver.
RSSI Calibration Page
7.5 REFERENCE CALIBRATION
In order for the radio to maintain an accurate frequency reference calibration of the radio’s frequency reference is
recommended to be checked after three years.
7.5.1 Equipment required for reference calibration
• An accurate 10 MHz source is needed, with a level between -5 and +20 dBm
• A MiMOMax GPIO/Ref/Alarm cable
• A connection to the radios CCMS
7.5.2 How to calibrate the reference
1. Feed the 10 MHz source into the reference inputs of the GPIO/Ref/Alarm connector (Brown and Red wires on the
MiMOMax GPIO/Ref/Alarm cable). Note: the reference signal is differential, but it does not normally cause any
problems if a non-differential signal is used, treat one of the differential connections as ground in this case.