2 SAFETY WARNINGS
2.1 MODIFICATIONS
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY
APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.
2.2 TRANSMITTER ANTENNA
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or
lesser) gain approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un
type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada.
Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type
d'antenne et son gain de sorte que la puissance isotrope rayonnée quivalente (p.i.r.e.) ne dépassepas l'intensité nécessaire
à l'établissement d'une communication satisfaisante.
2.3 SAFETY DISTANCE
Minimum Safe Distance from Antenna: To comply with safety requirements for human RF exposure in the USA, Canada and
other countries, no person shall be permitted to remain in the vicinity of the antenna of an operational MiMOMax Tornado
system at distances closer than the following:
General Public/Uncontrolled Use: 0.16m when using an 8dbi Panel Antenna with a MiMOMax 700MHz radio.
The above distances are based on procedures defined by regulatory standards for equipment operating at maximum power
and 100% duty cycle with a person located directly in front of the antenna in the main radiation lobe.
2.4 FCC RF EXPOSURE STATEMENT
The transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. The equipment
complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed
and operated with a minimum distance of 61cm between the radiator and any part of your body.
2.5 ELECTRICAL SAFETY CABLE SCREENING
Equipment connected to the protective earthing of the building installation through the mains connection or through other
equipment with a connection to protective earthing - and to a cable distribution system using coaxial cable, may in some
circumstances create a fire hazard. Connection to a cable distribution system has therefore to be provided through a device
providing electrical isolation below a certain frequency range (galvanic isolator, see EN 60728-11).
NOTE: In Norway, due to regulation for installations of cable distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller via annet jordtilkoplet utstyr - og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal det ved tilkopling av utstyret til kabel-TV nettet installeres en galvanisk isolator
mellom utstyret og kabel-TV nettet.
Utrustning som är kopplad till skyddsjord via jordat vägguttag och/eller via annan utrustning och samtidigt är kopplad till kabel-
TV nät kan i vissa fall medfõra risk fõr brand. Fõr att undvika detta skall vid anslutning av utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och kabel-TV nätet.
2.6 MAINS CONNECTION
The Mains connection of the supply providing the DC supply to the MiMOMax Tornado unit shall be either:
• PERMANENTLY CONNECTED EQUIPMENT.
• PLUGGABLE EQUIPMENT TYPE B.