These safety instructions must be followed to ensure your safety and prevent property damage. N A N O V I S I O N Otherwise, it may result in personal injury or property damage. Warning/Cautions -710 -730 -740 -750 UM - 430 UM UM UM UM User’s Manual http://www.nanovision.co.
Product Input/Output Connectors T a b l e o f - Do not insert any metal, such as chopsticks, coins, pins and steel, - If foreign material enters the product, disconnect the USB cable and contact a Service Center. C o n t e n t s User’s Manual Using DMB (UM-750 Only) -0 Do use the product near a microwave oven or a Instructions 4 notSafety refrigerator. -0 Electric wave Features or a radio wave may affect signal 6 Product reception. -0 Be withContents use of the Rod Antenna.
Safety Instructions These safety instructions must be followed to ensure your safety and prevent property damage. Warning/Cautions Otherwise, it may result in personal injury or property damage. Make sure to read the instructions carefully and use the product in the correct manner. Power Source: - Make sure to use USB Cable (DC 5V, 500mA) only. mimo doesn’ t require any additional power source Do not place mimo in a location exposed to moisture, dust, smoke, water, or in a car.
Product Input/Output Connectors - Do not insert any metal, such as chopsticks, coins, pins and steel, - If foreign material enters the product, disconnect the USB cable and contact a Service Center. Do not install mimo in an unstable location. - Otherwise, it may fall and cause personal injury and/or damage the product. Ensure that users do not disassemble, repair or modify the product themselves. - If the product needs to be repaired, contact a Service Center.
Product Features mimo is a USB powered monitor with Webcam, Mic, DMB TV, Touch Screen Display. With only USB cable connection, a user may utilize mimo as Multiple Input/Output device for Video Conference, Instant Messaging, News and Stock casting.
Package Contents Please make sure the following items are included with your monitor. Contact a local dealer to buy optional items. UM-430 UM-430 USB CABLE UM-710 UM-730, UM-740, UM750 UM-710/730/740/750 USB CABLE User’ s Manual Audio Cable(UM-730, UM-750) Install Disc Rod Antenna (UM-750) Extension Antenna (UM-750) ※ Package Contents are subject to vary upon each model If any items are missing, contact your dealer.
Connections and Installation mimo requires USB connection only. ⑥ ① ② ③ ④ ⑤ ①②③④ ① Emergency Power input : mimo doesn’ t require any additional power source except USB. Emergency Power input is for Factory or Technical Service purpose only.
Installing Monitor Driver (AutoRun) Insert the CD into the CD-ROM drive Please make sure that your mimo is connected to the PC (If the CD is not running automatically please doubleclick the“Mimo Drive”among the CD clontents) Installation takes about 1 minute. Do not power off or disconnect the USB cable until installation is completely finished. This may damage systems or may cause system errors. The mimo screen resolution is fixed for the best picture quality with each model. 1.
5. If you see following message window, select“I agree”to accept the terms of use 6. When the installation is complete, the mimo setting icon appears on your system tray and the connected USB monitor information will pop-up. 7. After finish installation of the mimo driver, please follow below steps for multi-monitor setting.
mimo display setting 1. When the mimo driver installation is complete, the mimo setting icon appears on your system tray. 2. Click-on mimo icon then you may see the mimo setup menu for Screen Resolution, Colors, Rotation, Extention and etc.
Installing Touch Screen Controller (UM-740/UM-750 only) 1. Selecting Controller If you see following message window, select“E2i Technologies, NTR, USB” and click“Install” . 2. Installing the Controller Click“Next”and follow on screen direction. Program will display the progress. 3. Finish Touch Screen Controller installation Click「Close」 or using keyboard.
4. Settings and Calibrations Check the monitor number of the installed mimo at“Display Properties” Right-click and Run the UPDD Consol (Pointer Device Setting) icon on system tray.
Select the monitor number of the installed mimo. Calibration The product is with factory default calibration value. If required user may execute Touch Screen Controller Calibration as follow. Calibration is very important procedure to align coordinates of the exact touch point on screen with mouse pointer. With the calibration user may utilize Touch Screen Control without distortion.
Touch + mark position in order then 「Confirm」 If calibration point inputs are correct click「Confirm」 In case any mistake in calibration points inputs click「Cancel」 or leave the screen untouched for about 10 seconds then the Calibration Data will be scrapped. ※ The calibrated Touch Screen coordinates may vary upon the lapse of usage time. Periodical calibration is recommended.
System Requirements & Restrictions 1. Operating Systems Windows XP - Service Pack 1 prior : Not supported - Service Pack 2 or after : Supported Windows 2000 - Service Pack 3 prior : Not supported - Service Pack 4 or after : Supported Windows Server 2003: Not supported Windows Vista: Supported except 64bit systems User may check the Operating System version by Right-click‘My Computer’→ ‘Properties’→‘System Properties’ 2. mimo is a USB monitor to be recognized as a Generic USB device.
Troubleshooting Before calling for assistance, please read carefully below. If you do need assistance, please call local service center or contact your dealer. Q A Q A No image on screen, I cannot turn on the mimo. Is USB cable connected and did you install mimo driver yet? Please run‘mimo Installation Software’in the CD. For more detail about driver installation, please refer to Connections & Installation chapter I cannot turn my mimo screen on. Please check if the USB cable is connected.
Q A Q A Q A I cannot boot my system after connecting mimo. in case i815 chipset One-Board Type PC system, please disable‘Legacy USB support’ option in system BIOS menu and reboot the system. - BIOS setup method may differ from PC to PC, please refer to the User manual of the PC. Please refer to Microsoft homepage for more detail. I cannot see DOS opening screen with mimo when my PC is booting up. mimo is a generic USB device.
Q mimo information remains in my‘Display Properties’even after disconnect or power off the mimo. A The deactivated USB information implies power off or disconnected USB monitor status. To delete the deactivated monitor information, please uninstall‘nanovision Mini Monitor’ driver. Once the driver is uninstalled, you may not use MIMO. To use mimo again please re-install the driver.
Specifications Model Name: MIMO UM-430 (4.3〃WQVGA), UM-710(7〃VGA) UM-730(7〃WVGA/Webcam /MIC), UM-740(7〃WVGA/Webcam/MIC/TSP) UM-750(7〃WVGA/Webcam/MIC/TSP/DMB) LCD Panel Size: 10.92 cm(UM-430), 17.78 cm(UM-710/730/740/750) Display Size: 97mm(H) x 57 mm(V), 152.4 mm(H) x 91.4 mm(V), Pixel Pitch: 0.198mm(H)x0.198mm(V), 0.1905mm(H)x0.1905mm(V) Number of Color: 16.7M Contrast: 400:1 Input Power: USB (DC 5V) Screen Resolution: WQVGA(480x272), WVGA(800x480) Power Consumption: 2W~4.