Specifications
2-32
Test drawing
Make test drawing to check blur or missing caused by nozzle clogging.
1
When <LOCAL> is displayed, press the
key.
2
Select [NOZZLE CHECK] with the or
key , and press the key.
• Select [HARDEN CHECK] to confirm whether the UV ink is cured or not.
( P.3-4)
3
Test drawing starts.
• The machine scans for UV irradiation to cure ink on
the drawn pattern. ( P.3-23)
• When the following message is displayed, it cannot print. Start drawing after the message has
disappeared.
“WATER NOT READY” :The water temperature in the water heating device has not
reached the predetermined value.
Check before starting
test drawing
• Is media set ?
( P.2-10)
• Is the origin position set ?
(P.2-28)
<LOCAL . 1>
TEST DRAW
NOZZ L E CHECK <ENT >
ENTER
** TEST DRAW **