Specifications
Table Of Contents
- TABLE OF CONTENTS
- CAUTION
- Foreword
- For safe operation
- How to Read This Operation Manual
- CHAPTER 1 Before Use
- CHAPTER 2 Basic Operations
- CHAPTER 3 Useful Function
- Changing origin
- Adjusting head gap
- When nozzles missing can not be improved
- Setting the print condition in a set
- Setting the print condition
- Setting media compensation
- Setting the print method
- Registering head gap value
- Set the scan width of the head
- Changing the UV illumination intensity
- Sets UV irradiation at starting/ ending of drawing
- Setting the priority
- Sets the cooling time per scan
- Initializing the settings
- Turning OFF the UV lamp
- Setting the UV lamp OFF duration
- Changing the UV illumination intensity
- MACHINE SETUP
- Other useful functions
- CHAPTER 4 How to care
- Maintaining
- Ink cartridge
- Washing cartridge
- Cleaning the flushing box
- Avoiding ink dripping at printing
- When the waste ink tray is full
- Setting nozzle face cleaning time
- Perform cleaning automatically when the power supply is turned on
- Preventing nozzle dropout while power-off
- Regular maintenance of white ink
- If blur or missing remains
- Wiper cleaning
- Refill antifreeze liquid
- Cleaning of the UV lamp filter
- Cleaning of the UV power supply filter
- Cleaning of the optional vacuum unit filter
- Replacing the mist fan filter
- Replacing UV lamp
- Checking method of UV illumination intensity
- Cleaning of the Ionizer
- Prevent the nozzle clogging of spot color
- CHAPTER 5 In Case of Trouble
- CHAPTER 6 Appendix

xii
WARNING
Power supply and voltage
• This unit contains parts applied high voltage.Carrying out electrical work by those unauthorized for that work is
prohibited.
• To prevent electrical shock, be sure to set OFF the main power circuit breaker and disconnect the power plug before
carrying out maintenance.For some units, capacitors may take one minute for discharging; therefore, start
maintenance work three minutes after setting OFF the main power circuit breaker and disconnecting the power plug.
• Be sure to carry out grounding work to prevent electrical shock.
• Use the unit under the powerspecifications given. Refer to “Connecting the Power Distribution Board” in the
Installation Guide.
• Use the unit under the power specifications given.Be sure to connect the power cable plug to a convenient
outlet grounded, or fire or electric shock might occur.or it may cause electrical shock.
• The main power circuit breaker should be set ON only by personnel with sufficient knowledge about operations
of this unit.
Power supply and voltage
• This device is equivalent to Class I laser device according to CDRHRegulation. LASER CAUTION Labelfor
CDRH regulation shown below isprovided with the device.
Handling of UV irradiation device
• Do not use the UV irradiation device in an ambience with a possibility of catching fire (gasoline, combustible
gas spray, thinner, lacquer, powder dust, etc.). In addition, do not put paper or cloth near or on the UV
irradiation device, or it may cause fire.or it may cause electrical shock.
• The UV lamp is made of glass andshould not be dropped, hit againstanything, given excessive force
orscratched, or it may cause damage tothe UV lamp.
• Do not break a used UV lamp; put itin a container and discard likewiseordinary fluorescent lamps accordingto
the local regulations. Breaking aUV lamp will cause glass fragments tobe scattered.
• Never look at the UV lamp being lit with your naked eyes,or it may cause pain in your eyes or visual
impairment.Be sure to wear safety glasses.
• Do not apply ultraviolet (UV) light directly to your skin,or it may cause irritation on your skin.
• Be sure to use only the UV lamp recommended by Mimaki,or it may cause fire or damages to the unit.Never
use UV lamps other than those recommended by Mimaki.We would take no responsibility for any troubles
caused through the use of a UV lamp not recommended by Mimaki.
• Do not touch the lamp on or right after the lamp off with bare hands to avoid from burn injury.Make sure to
replace the lamp after it cools down completely.
Handling the Anti-freezing liquid
• Use the exclusive Anti-freezing liquid by Mimaki ,or the heater may be damaged.
• If the Anti-freezing liquid or mixed soft water with anti-freezing liquid gets on the skin or clothes, immediately
wash it off with soap.
If you get the Anti-freezing liquid or mixed soft water with anti-freezing liquid in your eyes, immediately wash
your eyes with a lot of clean water.
Then, consult a doctor as soon as possible.If high temperature Anti-freezing liquid or mixed soft water with anti-
freezing liquid gets on the skin, immediately wash it off with soap and cool with iced water. Then, consult a
doctor as soon as possible.
• Before using the Anti-freezing liquid, be sure to read the Material Safety Data Sheet (MSDS).
• If you swallowed the Anti-freezing liquid or mixed soft water with antifreezing liquid accidentally, try to get to
vomit, and then consult a doctor as soon as possible.
• When unused the Anti-freezing liquid or used mixed soft water with anti-freezing liquid should discard as
followings,
• Incinerating the fluid which is absorbed to the sawdust or waste cloth.
• Entrust them to an industrial waste disposal contractor, clarifying their contents.
• Avoid ignition such as static electricity and impact spark.
• Be sure to wear goggles and gloves for handling the Anti-freezing liquid.










