Specifications
Table Of Contents
- TABLE OF CONTENTS
- CAUTION
- Foreword
- For safe operation
- How to Read This Operation Manual
- CHAPTER 1 Before Use
- CHAPTER 2 Basic Operations
- CHAPTER 3 Useful Function
- Changing origin
- Adjusting head gap
- When nozzles missing can not be improved
- Setting the print condition in a set
- Setting the print condition
- Setting media compensation
- Setting the print method
- Registering head gap value
- Set the scan width of the head
- Changing the UV illumination intensity
- Sets UV irradiation at starting/ ending of drawing
- Setting the priority
- Sets the cooling time per scan
- Initializing the settings
- Turning OFF the UV lamp
- Setting the UV lamp OFF duration
- Changing the UV illumination intensity
- MACHINE SETUP
- Other useful functions
- CHAPTER 4 How to care
- Maintaining
- Ink cartridge
- Washing cartridge
- Cleaning the flushing box
- Avoiding ink dripping at printing
- When the waste ink tray is full
- Setting nozzle face cleaning time
- Perform cleaning automatically when the power supply is turned on
- Preventing nozzle dropout while power-off
- Regular maintenance of white ink
- If blur or missing remains
- Wiper cleaning
- Refill antifreeze liquid
- Cleaning of the UV lamp filter
- Cleaning of the UV power supply filter
- Cleaning of the optional vacuum unit filter
- Replacing the mist fan filter
- Replacing UV lamp
- Checking method of UV illumination intensity
- Cleaning of the Ionizer
- Prevent the nozzle clogging of spot color
- CHAPTER 5 In Case of Trouble
- CHAPTER 6 Appendix

Refill antifreeze liquid
4-29
4
How to care
Refilling antifreeze liquid
If a lack of water error is displayed, refill antifreeze liquid-mixed water.
To fill with the water, refill about 200cc.
1
Mix antifreeze liquid with water.
(1) Mix 1 part antifreeze liquid with 2 parts water.
(2) Put the mixed water into a provided syringe.
2
Uncover the feed-water inlet and the air
vent.
3
Refill antifreeze liquid.
• Fill the antifreeze liquid from the feed-water inlet.
• Fill it up seeing the water gauge on the back of this
machine.
Displaying red on the water gauge indicates full.
4
Cover the feed-water inlet and the air
vent.
feed-water inlet
air vent cover
water gauge