Specifications
3-24
Setting weight of the empty cartridge
Enter weight of the empty cartridge. It is used for recalculating remaining amount of ink. (600ml ink only)
1
Press the key in the local mode.
2
Press the [MACHINE SET] by pressing the or
key, and press the key.
3
Select the [600ml CARTRIDGE] by pressing the
or key, and press the key.
4
Select cartridges by pressing the or key.
• The ink colors set in the cartridges are displayed as “MCYKW
C
L
”.
• When two cartridges of the same color are set as WW or
C
L
C
L
, they are displayed as W1W2 or
C
L
1
C
L
2.
5
Enter weight of the cartridge by pressing the
or key, and press the key.
• The number changes by 1 g.
6
Press the key several times to end the setting.
<LOCAL>
FUNCTION
FUNCT I ON
MACH I NE SE T < ENT >
ENTER
MACH I NE SE T
600ml CARTRIDGE<en t >
ENTER
MACH I NE SE T
CARTR I DGE : M
MACH I NE SE T
CASE WEIGHT =300g
ENTER
END