Specifications

2-6
Test drawing
Make test drawing in the specified direction to check whether there is nozzle clogging or other drawing failures
(such as wearing or missing).
1
Press the key in the local mode.
2
Select the drawing direction by pressing the
or key, and press the key.
Test drawing is started in the selected direction.
• SCAN DIR: Draws in the scan (widthwise) direction of the media.
FEED DIR: Draws in the feed (longwise) direction of the media.
3
Test drawing ends.
Y-bar evacuates from the table, and then the mode returns to the local.
4
Check result of drawing.
When the result is normal, finish the operation. ( P.2-8)
When the result is abnormal, execute head cleaning. ( P.2-7)
Check before starting
test drawing
Is media set? ( P.2-4) Is origin point set? ( P.3-2)
Normal pattern
Abnormal patterns
Nozzle drop out Nozzle missing Deflection
<LOCAL>
TEST
TEST DRAW
(SCAN DIR) <ENT>
TEST DRAW
(FEED DIR) <ENT>
ENTER
When FEED DIR is selected
When SCAN DIR is selected
Many lines are missing.
The lines are missing as if the
teeth are lost.
The distance between the
lines is narrowing or double
lines are formed.