Instruction manual

- 2.12 -
If there are nozzle clogging in ink firing condition
Cleaning ink heads
If a test pattern plotted is defective, execute the cleaning function to clean the associated ink head.
After cleaning the ink head, make the device plot a test pattern again. If the test pattern is
defective too, re-clean the ink head. Continue executing the cleaning function till a normal
test pattern is obtained.
If a normal test pattern cannot be obtained even after the cleaning function is
executed many times, clean the ink station interior (See page 4.8).
soft: Select this if there is any missing line.Cleaning is carried out for
a short period of time.
normal: Select this if any line is bent. Cleaning is carried out for a long
period of time and a large amount of ink is consumed.
strong: Select this if there are many missing portions.
STEPS:
1. Make sure the mode is LOCAL mode.
2. Press the [CLEANING] key.
3. Press the JOG keys [
] [ ] [ ] and [ ] to select
the ink head to be cleaned.
Each time a JOG key is pressed, the row of heads to be cleaned
changes from R to F (or F to R). The upper eight of test printing
indicates the R row of heads, and the lower eight indicates the
F row of heads.
4 types of head row can be selected: [1234], [5678], [ABCD],
and [EFGH].
4. Press the [ENTER] key.
5. Press the JOG keys [ ] and [ ] to select the type
of cleaning.
6. Press the [ENTER] key.
Cleaning starts.
The remaining time to cleaning is displayed on the second line
of LCD.
After completing the cleaning performance, the mode enters
the LOCAL mode.
<< LOCA L> >
width:1272mm
CLE AN I NG : 12 345678
SEL ECT : ABCDEFGH
CLE AN I NG : - - - - 5678
SEL ECT : ABCDEFGH
CLE AN I NG : - - - - 5678
SEL ECT :
AB CDEFGH
CLE AN I NG
TYP E :
norma l
CLE AN I NG
TYP E :
sof t
CLE AN I NG
00 :
**
:
**
<< LOCA L> >
width:1272mm
CLE AN I NG
PLEASE WA IT