- 3.20 -
Setting up auto-cleaning function [AUTO CLEAN]
Setup the auto-cleaning function. Printing failures may be remarkable on dusty locations or
locations with low temperature. Perform cleaning for each plot to prevent printing failures.
ON : The head is cleaned automatically.
OFF : The head is not cleaned automatically.
•When setting “AUTO CLEAN” ON, before starting print, remove the ink
adhered around the head . (See page 4.23)
If executing cleaning without removing the ink around the head, it may
cause the nozzle condition worse.
STEPS:
1. Select a type. (See page 3.3)
Here, select [Type.1].
2. Press the [ENTER] key.
3. Press the JOG keys [
] and [ ] to select
[AUTO CLEAN].
4. Press the [ENTER] key.
5. Press the JOG keys [
] and [ ] to select [ON] or
[OFF] of the [AUTO CLEAN].
Here, select [ON].
6. Press the [ENTER] key.
7. Press the [END] key twice.
The menu returns to the LOCAL mode.
SETUP
SELECT :
TY PE . 1
T YPE1
MED I A COMP. <ent >
T YPE1
AUTO CLEAN<ent>
<< LOCA L> >
width:1272mm
T YPE1
AUTO CLEAN<ent>
T YPE1
AUTO CLEAN : OFF
TYPE1
AUTO CLEAN : ON