Instruction manual

– 3.18 –
3-4-6. Stripes are always drawn at the time of scanning
Problems Black or white stripes are always drawn at the time of scanning.
Causes 1) The value of [MEDIA COMP.] is not correct.
When the media is changed, perform SETUP and [MEDIA COMP.]
to set values which suit the media.
2) A medium that is heavier than the specification is placed. (For the case
where black stripes appear)
3) Thickker media is used. However, the settings for light-weight medium
remain.
4) The value of MEDIA CORRECTION is not correct.
When the media is changed, perform [SETUP - MEDIA COMP]
to set values which suit the media.
Checking procedures 1) Perform SETUP and [MEDIA COMP.] to check that the value of
[MEDIA COMP.] is correct.
2) Medium weight measurement (medium of which weight is 10kg or less
is recommended)
3) Check whether or not the distance compensation matches the medium
used.
Remedies 1) Same as 1) [ 3-4-6. Medium feeding failure.]
2) Use a medium of which weight is 10kg or less.
3) Set the correction value.
Priority setting Media correction value used
Panel Media correction value set by the user at the time of media correction.
Host Correction value specified by command.