Instruction manual
– 6.9 –
6-2-3. Adjustment of the Linear sensor PCB assy height
[The case that needs adjustment]
• In the case where the Linear sensor PCB assy has been replaced
• In the case where the Linear encoder scale has been replaced
[Tools to be used]
• Phillips screwdriver (No.2 for M3 to M5)
[Adjusting procedure]
1) Loosen the screws in the X-motor bracket.
2) Within the movable range of the slider, move the assy up and down so that the gap between
the linear encoder scale and linear sensor PCB is about 1mm±0.5mm.
Linear sensor PCB assy
Mounting screw